364 research outputs found

    Clinical risk factors of colorectal cancer in patients with serrated polyposis syndrome: a multicentre cohort analysis

    Get PDF
    OBJECTIVE: Serrated polyposis syndrome (SPS) is accompanied by an increased risk of colorectal cancer (CRC). Patients fulfilling the clinical criteria, as defined by the WHO, have a wide variation in CRC risk. We aimed to assess risk factors for CRC in a large cohort of patients with SPS and to evaluate the risk of CRC during surveillance. DESIGN: In this retrospective cohort analysis, all patients with SPS from seven centres in the Netherlands and two in the UK were enrolled. WHO criteria were used to diagnose SPS. Patients who only fulfilled WHO criterion-2, with IBD and/or a known hereditary CRC syndrome were excluded. RESULTS: In total, 434 patients with SPS were included for analysis; 127 (29.3%) were diagnosed with CRC. In a per-patient analysis ≥1 serrated polyp (SP) with dysplasia (OR 2.07; 95% CI 1.28 to 3.33), ≥1 advanced adenoma (OR 2.30; 95% CI 1.47 to 3.67) and the fulfilment of both WHO criteria 1 and 3 (OR 1.60; 95% CI 1.04 to 2.51) were associated with CRC, while a history of smoking was inversely associated with CRC (OR 0.36; 95% CI 0.23 to 0.56). Overall, 260 patients underwent surveillance after clearing of all relevant lesions, during which two patients were diagnosed with CRC, corresponding to 1.9 events/1000 person-years surveillance (95% CI 0.3 to 6.4). CONCLUSION: The presence of SPs containing dysplasia, advanced adenomas and/or combined WHO criteria 1 and 3 phenotype is associated with CRC in patients with SPS. Patients with a history of smoking show a lower risk of CRC, possibly due to a different pathogenesis of disease. The risk of developing CRC during surveillance is lower than previously reported in literature, which may reflect a more mature multicentre cohort with less selection bias

    An appropriate tool for entrepreneurial learning in SMEs? The case of the 20Twenty Leadership Programme

    Get PDF
    The 20Twenty Leadership Programme was developed by Cardiff Metropolitan University as an executive education programme to be delivered within South Wales to small businesses. It is funded by the European Social Fund (ESF) and administered by the Welsh European Funding Office and has the key aim of developing SME’s growth potential via a range of leadership and management skills, including a focus on ‘soft’ skills. The focus of this paper is to place the 20Twenty Leadership Programme within the wider context of entrepreneurship policy and SME training initiatives in particular, and then to examine the rationale and delivery methods of the Programme in relation to these. It also reflects on the Programme’s success (or otherwise) to date where possible. Finally, the paper seeks to suggest fruitful areas of further research both in terms of the 20Twenty Leadership Programme itself, but also with regard to evaluation in relation to other parallel programmes, and to SME training initiatives more generally

    A Pilot Study on Automatic Three-Dimensional Quantification of Barrett’s Esophagus for Risk Stratification and Therapy Monitoring

    Get PDF
    Background & Aims Barrett’s epithelium measurement using widely accepted Prague C&M classification is highly operator dependent. We propose a novel methodology for measuring this risk score automatically. The method also enables quantification of the area of Barrett’s epithelium (BEA) and islands, which was not possible before. Furthermore, it allows 3-dimensional (3D) reconstruction of the esophageal surface, enabling interactive 3D visualization. We aimed to assess the accuracy of the proposed artificial intelligence system on both phantom and endoscopic patient data. Methods Using advanced deep learning, a depth estimator network is used to predict endoscope camera distance from the gastric folds. By segmenting BEA and gastroesophageal junction and projecting them to the estimated mm distances, we measure C&M scores including the BEA. The derived endoscopy artificial intelligence system was tested on a purpose-built 3D printed esophagus phantom with varying BEAs and on 194 high-definition videos from 131 patients with C&M values scored by expert endoscopists. Results Endoscopic phantom video data demonstrated a 97.2% accuracy with a marginal ± 0.9 mm average deviation for C&M and island measurements, while for BEA we achieved 98.4% accuracy with only ±0.4 cm2 average deviation compared with ground-truth. On patient data, the C&M measurements provided by our system concurred with expert scores with marginal overall relative error (mean difference) of 8% (3.6 mm) and 7% (2.8 mm) for C and M scores, respectively. Conclusions The proposed methodology automatically extracts Prague C&M scores with high accuracy. Quantification and 3D reconstruction of the entire Barrett’s area provides new opportunities for risk stratification and assessment of therapy response

    Narrow-band imaging does not improve detection of colorectal polyps when compared to conventional colonoscopy: a randomized controlled trial and meta-analysis of published studies

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A colonoscopy may frequently miss polyps and cancers. A number of techniques have emerged to improve visualization and to reduce the rate of adenoma miss.</p> <p>Methods</p> <p>We conducted a randomized controlled trial (RCT) in two clinics of the Gastrointestinal Department of the Sanitas University Foundation in Bogota, Colombia. Eligible adult patients presenting for screening or diagnostic elective colonoscopy were randomlsy allocated to undergo conventional colonoscopy or narrow-band imaging (NBI) during instrument withdrawal by three experienced endoscopists. For the systematic review, studies were identified from the Cochrane Library, PUBMED and LILACS and assessed using the Cochrane risk of bias tool.</p> <p>Results</p> <p>We enrolled a total of 482 patients (62.5% female), with a mean age of 58.33 years (SD 12.91); 241 into the intervention (NBI) colonoscopy and 241 into the conventional colonoscopy group. Most patients presented for diagnostic colonoscopy (75.3%). The overall rate of polyp detection was significantly higher in the conventional group compared to the NBI group (RR 0.75, 95%CI 0.60 to 0.96). However, no significant differences were found in the mean number of polyps (MD -0.1; 95%CI -0.25 to 0.05), and the mean number of adenomas (MD 0.04 95%CI -0.09 to 0.17). Meta-analysis of studies (regardless of indication) did not find any significant differences in the mean number of polyps (5 RCT, 2479 participants; WMD -0.07 95% CI -0.21 to 0.07; I2 68%), the mean number of adenomas (8 RCT, 3517 participants; WMD -0.08 95% CI -0.17; 0.01 to I2 62%) and the rate of patients with at least one adenoma (8 RCT, 3512 participants, RR 0.96 95% CI 0.88 to 1,04;I2 0%).</p> <p>Conclusion</p> <p>NBI does not improve detection of colorectal polyps when compared to conventional colonoscopy (Australian New Zealand Clinical Trials Registry <a href="http://www.anzctr.org.au/ACTRN12610000456055.aspx">ACTRN12610000456055</a>).</p

    Risk-stratified faecal immunochemical testing (FIT) for urgent colonoscopy in Lynch syndrome during the COVID-19 pandemic

    Get PDF
    BACKGROUND: Lynch syndrome is a hereditary cancer disease resulting in an increased risk of colorectal cancer. Herein, findings are reported from an emergency clinical service implemented during the COVID-19 pandemic utilizing faecal immunochemical testing ('FIT') in Lynch syndrome patients to prioritize colonoscopy while endoscopy services were limited. METHODS: An emergency service protocol was designed to improve colonoscopic surveillance access throughout the COVID-19 pandemic in England for people with Lynch syndrome when services were extremely restricted (1 March 2020 to 31 March 2021) and promoted by the English National Health Service. Requests for faecal immunochemical testing from participating centres were sent to the National Health Service Bowel Cancer Screening South of England Hub and a faecal immunochemical testing kit, faecal immunochemical testing instructions, paper-based survey, and pre-paid return envelope were sent to patients. Reports with faecal haemoglobin results were returned electronically for clinical action. Risk stratification for colonoscopy was as follows: faecal haemoglobin less than 10 µg of haemoglobin/g of faeces (µg/g)-scheduled within 6-12 weeks; and faecal haemoglobin greater than or equal to 10 µg/g-triaged via an urgent suspected cancer clinical pathway. Primary outcomes of interest included the identification of highest-risk Lynch syndrome patients and determining the impact of faecal immunochemical testing in risk-stratified colonoscopic surveillance. RESULTS: Fifteen centres participated from June 2020 to March 2021. Uptake was 68.8 per cent amongst 558 patients invited. For 339 eligible participants analysed, 279 (82.3 per cent) had faecal haemoglobin less than 10 µg/g and 60 (17.7 per cent) had faecal haemoglobin greater than or equal to 10 µg/g. In the latter group, the diagnostic accuracy of faecal immunochemical testing was 65.9 per cent and escalation to colonoscopy was facilitated (median 49 versus 122 days, χ2 = 0.0003, P < 0.001). CONCLUSION: Faecal immunochemical testing demonstrated clinical value for Lynch syndrome patients requiring colorectal cancer surveillance during the pandemic in this descriptive report of an emergency COVID-19 response service. Further longitudinal investigation on faecal immunochemical testing efficacy in Lynch syndrome is warranted and will be examined under the 'FIT for Lynch' study (ISRCTN15740250)

    Balancing Selection of a Frame-Shift Mutation in the MRC2 Gene Accounts for the Outbreak of the Crooked Tail Syndrome in Belgian Blue Cattle

    Get PDF
    We herein describe the positional identification of a 2-bp deletion in the open reading frame of the MRC2 receptor causing the recessive Crooked Tail Syndrome in cattle. The resulting frame-shift reveals a premature stop codon that causes nonsense-mediated decay of the mutant messenger RNA, and the virtual absence of functional Endo180 protein in affected animals. Cases exhibit skeletal anomalies thought to result from impaired extracellular matrix remodeling during ossification, and as of yet unexplained muscular symptoms. We demonstrate that carrier status is very significantly associated with desired characteristics in the general population, including enhanced muscular development, and that the resulting heterozygote advantage caused a selective sweep which explains the unexpectedly high frequency (25%) of carriers in the Belgian Blue Cattle Breed

    A multi-centre polyp detection and segmentation dataset for generalisability assessment

    Get PDF
    Polyps in the colon are widely known cancer precursors identified by colonoscopy. Whilst most polyps are benign, the polyp’s number, size and surface structure are linked to the risk of colon cancer. Several methods have been developed to automate polyp detection and segmentation. However, the main issue is that they are not tested rigorously on a large multicentre purpose-built dataset, one reason being the lack of a comprehensive public dataset. As a result, the developed methods may not generalise to different population datasets. To this extent, we have curated a dataset from six unique centres incorporating more than 300 patients. The dataset includes both single frame and sequence data with 3762 annotated polyp labels with precise delineation of polyp boundaries verified by six senior gastroenterologists. To our knowledge, this is the most comprehensive detection and pixel-level segmentation dataset (referred to as PolypGen) curated by a team of computational scientists and expert gastroenterologists. The paper provides insight into data construction and annotation strategies, quality assurance, and technical validation

    A Step Forward in Molecular Diagnostics of Lyssaviruses – Results of a Ring Trial among European Laboratories

    Get PDF
    Rabies is a lethal and notifiable zoonotic disease for which diagnostics have to meet the highest standards. In recent years, an evolution was especially seen in molecular diagnostics with a wide variety of different detection methods published. Therefore, a first international ring trial specifically designed on the use of reverse transcription polymerase chain reaction (RT-PCR) for detection of lyssavirus genomic RNA was organized. The trial focussed on assessment and comparison of the performance of conventional and real-time assays. In total, 16 European laboratories participated. All participants were asked to investigate a panel of defined lyssavirus RNAs, consisting of Rabies virus (RABV) and European bat lyssavirus 1 and 2 (EBLV-1 and -2) RNA samples, with systems available in their laboratory. The ring trial allowed the important conclusion that conventional RT-PCR assays were really robust assays tested with a high concordance between different laboratories and assays. The real-time RT-PCR system by Wakeley et al. (2005) in combination with an intercalating dye, and the combined version by Hoffmann and co-workers (2010) showed good sensitivity for the detection of all RABV samples included in this test panel. Furthermore, all used EBLV-specific assays, real-time RT-PCRs as well as conventional RT-PCR systems, were shown to be suitable for a reliable detection of EBLVs. It has to be mentioned that differences were seen in the performance between both the individual RT-PCR systems and the laboratories. Laboratories which used more than one molecular assay for testing the sample panel always concluded a correct sample result. Due to the markedly high genetic diversity of lyssaviruses, the application of different assays in diagnostics is needed to achieve a maximum of diagnostic accuracy. To improve the knowledge about the diagnostic performance proficiency testing at an international level is recommended before using lyssavirus molecular diagnostics e.g. for confirmatory testing

    Narrow band imaging for the detection of gastric intestinal metaplasia and dysplasia during surveillance endoscopy

    Get PDF
    Background: Surveillance of premalignant gastric lesions relies mainly on random biopsy sampling. Narrow band imaging (NBI) may enhance the accuracy of endoscopic surveillance of intestinal metaplasia (IM) and dysplasia. We aimed to compare the yield of NBI to white light endoscopy (WLE) in the surveillance of patients with IM and dysplasia. Methods: Patients with previously identified gastric IM or dysplasia underwent a surveillance endoscopy. Both WLE and NBI were performed in all patients during a single procedure. The sensitivity of WLE and NBI for the detection of premalignant lesions was calculated by correlating endoscopic findings to histological diagnosis. Results: Forty-three patients (28 males and 15 females, mean age 59 years) were included. IM was diagnosed in 27 patients; 20 were detected by NBI and WLE, four solely by NBI and three by random biopsies only. Dysplasia was detected in seven patients by WLE and NBI and in two patients by random biopsies only. Sixty-eight endoscopically detected lesions contained IM: 47 were detected by WLE and NBI, 21 by NBI only. Nine endoscopically detected lesions demonstrated dysplasia: eight were detected by WLE and NBI, one was detected by NBI only. The sensitivity, specificity, positive and negative predictive values for detection of premalignant lesions were 71, 58, 65 and 65% for NBI and 51, 67, 62 and 55% for WLE, respectively. Conclusions: NBI increases the diagnostic yield for detection of advanced premalignant gastric lesions compared to routine WLE
    corecore